Time zones |
24 to 46 ‘hard’ time zones plus 16 ‘soft’ time zones |
Communications bus |
RS-485 |
12 VDC auxiliary power output |
700mA (max.) |
Operating temperature |
0 to 50C |
Strobe |
1 |
Sirens |
Two 8 Ohm sirens, internal and external. The external siren is monitored for tamper conditions |
Anti-passback |
Yes |
Maximum cabling distance |
1,500 m (unless extended by LAN Isolation Interfaces) |
Input voltage |
16V, 1.5A from supplied transformer (space for 7 Ah battery allocated) |
Relays or outputs |
Use expansion modules and DGPs to add up to 255 relays or outputs |
Outputs on board -relays |
Exterior siren, interior siren, strobe |
Door groups |
expandable to 255 |
Alarm groups |
255 |
Dimensions in enclosure W x H x D |
345 x 450 x 73 mm |
Floor groups |
Expandable to 128 |
Battery test |
Dynamic battery testing |
Macro logic programs |
24 |
Users |
50 (expandable to 65,535) |
Holidays or Special days |
24 |
Operating Current |
200mA maximum (no peripheral devices fitted) |
Reporting Formats |
CID, Extended high speed, Serial STU, Tecom Dialler, Direct Line and more |
Management Software Connection |
IP connection using TS0898 Ethernet Interface RS-232 serial connection using TS0091 Computer and Printer Interface RS-232 serial connection using the Challenger panel’s onboard serial port connection only, typically used by installers) Modem connection using the Challenger panel’s onboard modem (dialer) Modem connection using an external modem connected to TS0091 |
Alarm Log |
100 to 1,000 |
Max access doors - with TS0867 or TS0866 |
16 on panel plus 48 on 4-Door Controllers |
Max system inputs |
256 |
Access log |
100 to 1,000 |