System areas |
16 |
Inputs on board |
16 |
Max system inputs |
256 |
Outputs on board - relays |
Exterior siren, interior siren, strobe |
12 VDC auxiliary power output |
700mA (max.) |
Max access control doors - when using TS0867 or TS0866 |
16 on panel plus 48 on 4-Door Controllers |
Anti-passback |
Yes |
Management software connection options |
IP connection using TS0898 Ethernet Interface RS-232 serial connection using TS0091 Computer and Printer Interface RS-232 serial connection using the Challenger panel’s onboard serial port connection only, typically used by installers) Modem connection using the Challenger panel’s onboard modem (dialer) Modem connection using an external modem connected to TS0091 |
Input voltage |
16V, 1.5A from supplied transformer (space for 7 Ah battery allocated) |
Operating Current |
200mA maximum (no peripheral devices fitted) |
Battery test |
Dynamic battery testing |
Relays or outputs |
Use expansion modules and DGPs to add up to 255 relays or outputs |
Macro logic programs |
24 |
Sirens |
Two 8 Ohm sirens, internal and external. The external siren is monitored for tamper conditions |
Strobe |
1 |
Reporting formats |
CID, Extended high speed, Serial STU, Tecom Dialler, Direct Line and more |
Communications bus |
RS-485 |
Maximum cabling distance |
1,500 m (unless extended by LAN Isolation Interfaces) |
Users |
50 (expandable to 65,535) |
Alarm groups |
255 |
Door groups |
expandable to 255 |
Floor groups |
Expandable to 128 |
Alarm log |
100 to 1,000 |
Access log |
100 to 1,000 |
Holidays or Special days |
24 |
Time zones |
24 to 46 ‘hard’ time zones plus 16 ‘soft’ time zones |
Operating temperature |
0 to 50c |
Dimensions in enclosure - W x H x D |
345 x 450 x 73 mm |